
BRL-K790 Application of paint systems on steel tanks, pipes & fittings
Receive a quote tailored to your needs
The following areas are applicable:
1 | Factory applied: Internal coatings for liquid fuels certified in accordance with the requirements of BRL-K779 for underground and above ground PGS 16, PGS 19, PGS 28 of PGS 30 steel tanks; External coatings certified to the requirements of BRL-K768 or BRL-K745 for underground PGS 16 or PGS 28 steel tanks, pipes and fittings. |
2 | In-situ application of internal or external coatings certified in accordance with the requirements of BRL-K745, BRL-K768 or BRL-K779 on PGS 16, PGS 19, PGS 28 or PGS 30 steel tanks. |
3 | In-situ repair of small areas of internal or external coatings certified in accordance with the requirements of BRL-K745, BRL-K768 or BRL-K779 on PGS 16, PGS 19 or PGS 28 steel tanks or of internal coatings certified in accordance with the requirements of BRL-K779 on PGS 29 or PGS 30 steel tanks. |
4 | In-situ application of above ground PGS 29 steel tanks of internal coatings for liquid fuels certified in accordance with the requirements of BRL-K779. |
5 | In-situ application of external paint systems on above ground PGS 29 or PGS 30 steel tanks. |
6 | Factory application of external paint systems on above ground PGS 30 steel tanks. |
For whom?
Relevant to applicators, coating manufacturers and tank manufacturers.
When is it necessary?
Companies covered by the Activities Decree (Activiteitenbesluit = BARIM) are legally required to have their chemical storage installation to be installed by an installer certified in accordance with BRL SIKB 7800/BRL-K903. Certified installers must submit an approved RI&E (Risk Inventory & Evaluation) before a certificate in accordance with BRL SIKB 7800/BRL-K903 can be issued. The tanks and spill containers required for the storage of chemicals will be part of this RI&E.
The RI&E of each installation can be streamlined when use is made of certified components. In such cases, the RI&E aspects related to the certified products, are not required. Storage tanks and spill containers, coated or panted with certified products, in accordance with the requirements of BRL-K790, will be in accordance with the requirements of the BARIM, RARIM and BRL SIKB 7800/BRL-K903.
Interested?
If you are interested in certification, please complete the application form. If you have any questions, please contact our sales office.
Note:
This Evaluation Guideline is only available in Dutch.
BRL-K779/04 Internal coatings for storage of flammable fluids in steel tanks
Internal coatings of steel tanks in accordance with the requirements of BRL-K779 are suitable for the storage of fuels according to the PGS-Class 1, Class 2 or Class 3 with a storage temperature between -20°C to + 40°C.

BRL-K21012/01 External paint systems for above ground steel tanks
Paint systems certified to the requirements of BRL-K21012 are suitable for the external protection of above ground steel tanks.

BRL-K768/03 External epoxy coatings of underground steel tanks, pipes & fittings
Coatings certified to the requirements of BRL-K768 are suitable for the external protection of underground steel tanks, pipes and fittings. Tanks protected with these coatings can be installed in areas with a high ground water table. Also, these coatings can be used in combination with a cathodic protection system.

BRL-K21013/01 Containertanks
Container tanks are used as stationary storage tank for atmospheric storage of liquids. The stored liquids are flammable liquids with a flash point higher or equal to 55 ºC.

BRL-K21051/01 Steel tanks and spill containers
Deze beoordelingsrichtlijn voorziet in stalen tanks en opvangbakken bestemd om toegepast te worden in stationaire tankinstallaties voor de atmosferische opslag van vloeistoffen.
