BRL 5605 Plastics piping systems of PB intended for heating installations: radiatorconnections
The products according BRL 5605 are applicable for piping systems in underfloor heating systems at a design (working) overpressure of 6 bar according the temperature profile class 5 in table 1.
Receive a quote tailored to your needs
Tabel 1 – Temperature profile during 50 years
Temperature [ ºC] | Time | Overall service coëfficiënt | |
Tcold | 20 | 14 years | 1,25 |
Tdesign | 60+80 | 25 years+10 years | 1,5 |
Tmax | 90 | 1 years | 1,3 |
T malfunction | 100 | 100 hours | 1,0 |
Remark: the mentioned temperature profile is in accordance with class 5 of ISO 10508. |
PB piping systems for radiator connections which are designed according class 5 may also be used for class 4 floorheating systems.
Installers/plumbers, architects, contractors, municipalities, housing association